Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biofabrication ; 14(3)2022 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-35344936

RESUMO

Cancer continues to be a leading cause of mortality in modern societies; therefore, improved and more reliablein vitrocancer models are needed to expedite fundamental research and anti-cancer drug development. Here, we describe the use of a miniaturized continuous stirred tank reactor (mCSTR) to first fabricate and mature cancer spheroids (i.e. derived from MCF7 cells, DU145 cells, and a mix of MCF7 cells and fibroblasts), and then to conduct anti-cancer drug assays under continuous perfusion. This 3 ml mCSTR features an off-center agitation system that enables homogeneous chaotic laminar mixing at low speeds to support cell aggregation. We incubated cell suspensions for 3 d in ultra-low-attachment plates to allow formation of discoid cell aggregates (∼600µm in diameter). These cell aggregates were then transferred into mCSTRs and continuously fed with culture medium. We characterized the spheroid morphology and the expression of relevant tumor biomarkers at different maturation times for up to 4 weeks. The spheroids progressively increased in size during the first 5-6 d of culture to reach a steady diameter between 600 and 800µm. In proof-of-principle experiments, we demonstrated the use of this mCSTR in anti-cancer drug testing. Three drugs commonly used in breast cancer treatment (doxorubicin, docetaxel, and paclitaxel) were probed at different concentrations in MCF7-derived spheroids. In these experiments, we evaluated cell viability, glucose consumption, spheroid morphology, lactate dehydrogenase activity, and the expression of genes associated with drug resistance (ABCB1andABCC1) and anti-apoptosis (Bcl2). We envision the use of this agitated system as a tumor-on-a-chip platform to expedite efficacy and safety testing of novel anti-cancer drugs and possibly in personalized medicine applications.


Assuntos
Antineoplásicos , Neoplasias da Mama , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular , Feminino , Humanos , Impressão Tridimensional , Esferoides Celulares
2.
Diagnostics (Basel) ; 11(2)2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33578665

RESUMO

Massive worldwide serological testing for SARS-CoV-2 is needed to determine the extent of virus exposure in a particular region, the ratio of symptomatic to asymptomatic infected persons, and the duration and extent of immunity after infection. To achieve this, the development and production of reliable and cost-effective SARS-CoV-2 antigens is critical. We report the bacterial production of the peptide S-RBDN318-V510, which contains the receptor-binding domain of the SARS-CoV-2 spike protein (region of 193 amino acid residues from asparagine-318 to valine-510) of the SARS-CoV-2 spike protein. We purified this peptide using a straightforward approach involving bacterial lysis, his-tag-mediated affinity chromatography, and imidazole-assisted refolding. The antigen performances of S-RBDN318-V510 and a commercial full-length spike protein were compared in ELISAs. In direct ELISAs, where the antigen was directly bound to the ELISA surface, both antigens discriminated sera from non-exposed and exposed individuals. However, the discriminating resolution was better in ELISAs that used the full-spike antigen than the S-RBDN318-V510. Attachment of the antigens to the ELISA surface using a layer of anti-histidine antibodies gave equivalent resolution for both S-RBDN318-V510 and the full-length spike protein. Results demonstrate that ELISA-functional SARS-CoV-2 antigens can be produced in bacterial cultures, and that S-RBDN318-V510 may represent a cost-effective alternative to the use of structurally more complex antigens in serological COVID-19 testing.

3.
Anal Methods ; 13(2): 169-178, 2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33399137

RESUMO

We demonstrate a loop-mediated isothermal amplification (LAMP) method to detect and amplify SARS-CoV-2 genetic sequences using a set of in-house designed initiators that target regions encoding the N protein. We were able to detect and amplify SARS-CoV-2 nucleic acids in the range of 62 to 2 × 105 DNA copies by this straightforward method. Using synthetic SARS-CoV-2 samples and RNA extracts from patients, we demonstrate that colorimetric LAMP is a quantitative method comparable in diagnostic performance to RT-qPCR (i.e., sensitivity of 92.85% and specificity of 81.25% in a set of 44 RNA extracts from patients analyzed in a hospital setting).


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA/análise , SARS-CoV-2/química , Carga Viral/métodos , COVID-19/diagnóstico , Colorimetria/métodos , Proteínas do Nucleocapsídeo de Coronavírus , DNA/análise , DNA/química , Corantes Fluorescentes/química , Humanos , Substâncias Intercalantes/química , Fenolsulfonaftaleína/química , Fosfoproteínas , RNA/química
4.
PLoS One ; 15(8): e0237418, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32790779

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has crudely demonstrated the need for massive and rapid diagnostics. By the first week of July, more than 10,000,000 positive cases of COVID-19 have been reported worldwide, although this number could be greatly underestimated. In the case of an epidemic emergency, the first line of response should be based on commercially available and validated resources. Here, we demonstrate the use of the miniPCR, a commercial compact and portable PCR device recently available on the market, in combination with a commercial well-plate reader as a diagnostic system for detecting genetic material of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causal agent of COVID-19. We used the miniPCR to detect and amplify SARS-CoV-2 DNA sequences using the sets of initiators recommended by the World Health Organization (WHO) for targeting three different regions that encode for the N protein. Prior to amplification, samples were combined with a DNA intercalating reagent (i.e., EvaGreen Dye). Sample fluorescence after amplification was then read using a commercial 96-well plate reader. This straightforward method allows the detection and amplification of SARS-CoV-2 nucleic acids in the range of ~625 to 2×105 DNA copies. The accuracy and simplicity of this diagnostics strategy may provide a cost-efficient and reliable alternative for COVID-19 pandemic testing, particularly in underdeveloped regions where RT-QPCR instrument availability may be limited. The portability, ease of use, and reproducibility of the miniPCR makes it a reliable alternative for deployment in point-of-care SARS-CoV-2 detection efforts during pandemics.


Assuntos
Betacoronavirus/genética , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Sequência de Bases , Betacoronavirus/química , COVID-19 , Infecções por Coronavirus/virologia , Proteínas do Nucleocapsídeo de Coronavírus , DNA Viral/genética , Confiabilidade dos Dados , Humanos , Proteínas do Nucleocapsídeo/genética , Pandemias , Fosfoproteínas , Pneumonia Viral/virologia , Reação em Cadeia da Polimerase/economia , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade
5.
Materials (Basel) ; 12(18)2019 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-31514390

RESUMO

The ideal in vitro recreation of the micro-tumor niche-although much needed for a better understanding of cancer etiology and development of better anticancer therapies-is highly challenging. Tumors are complex three-dimensional (3D) tissues that establish a dynamic cross-talk with the surrounding tissues through complex chemical signaling. An extensive body of experimental evidence has established that 3D culture systems more closely recapitulate the architecture and the physiology of human solid tumors when compared with traditional 2D systems. Moreover, conventional 3D culture systems fail to recreate the dynamics of the tumor niche. Tumor-on-chip systems, which are microfluidic devices that aim to recreate relevant features of the tumor physiology, have recently emerged as powerful tools in cancer research. In tumor-on-chip systems, the use of microfluidics adds another dimension of physiological mimicry by allowing a continuous feed of nutrients (and pharmaceutical compounds). Here, we discuss recently published literature related to the culture of solid tumor-like tissues in microfluidic systems (tumor-on-chip devices). Our aim is to provide the readers with an overview of the state of the art on this particular theme and to illustrate the toolbox available today for engineering tumor-like structures (and their environments) in microfluidic devices. The suitability of tumor-on-chip devices is increasing in many areas of cancer research, including the study of the physiology of solid tumors, the screening of novel anticancer pharmaceutical compounds before resourcing to animal models, and the development of personalized treatments. In the years to come, additive manufacturing (3D bioprinting and 3D printing), computational fluid dynamics, and medium- to high-throughput omics will become powerful enablers of a new wave of more sophisticated and effective tumor-on-chip devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...